Showing all 8 results
- Sort by:
AVAILABILITY: In stock
AVAILABILITY: In stock
AVAILABILITY: In stock
3 Part Differential Analyze
- Impedance platelet aggregometry and
- colorimetric method
- Throughput: 60 samples/hour
- Whole blood, pre-diluted blood
- 21 report parameters and 3 histograms
- Environmental friendly cyanide-free reagents
- Up to 14 alarm information of para-morphia cell
- Large colour LED display with high resolution
- Up to 10,000 sample storage capacity
- Optional Bar Code Reader
AVAILABILITY: In stock
Semi-Automated Biochemistry Analyzer
- 8 assay modes Preloaded test protocols
- 100 Open Tests Programmes
- 32 µl Quartz flow cell, minimum aspiration of 200 µl Real time graph display
- Daily and Monthly QC for 3 levels with LJ Graph 5000 Patient Data Storage
- Designed for various assays Clinical Chemistry Special Proteins
- Drugs of Abuse Therapeutic Drugs Electrolyte
Technical Specifications
Assay Types/Modes Open system / 8 modes (Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and
Sample Blank Non Linear)
Number of Tests 100
Sample Type Serum / Urine / Plasma
Light Source 6 V, 10 W Quartz Halogen Lamp (Life Span approx 2000 Hours)
Measurement Method Monochromatic and Bichromatic
Photodiodes One Silicon photodiode
Wavelength (in Filter wheel) 6 Filters (340, 405, 505, 546, 578, 620) and 2 Free positions
Absorbance Range 0 – 2.5 Absorbance
Resolution 0.0001
Stray light ≥ 2.3 Absorbance
Delay/Incubation Time 3 – 999 seconds
Read Time 3 – 999 seconds for end point and 30 – 999 for rate and fixed time.
Types of Test ware Flowcell
Flowcell Volume 32 µl Quartz
Display 240 x 128 pixel blue color graphical LCD with LED backlight.
Keyboard Keypad with 33 Keys
Printer In built 384 dots Thermal Printer (Positioning on Top)
PC Communication 9 pin D type Serial Connector
PC Software Optional
Memory FLASH
Storage 5000 Patient Reports
150 Daily QC
3 Month QC Data
Result Reports Collated by ID, Date and Test
Quality Controls Daily and Monthly for 3 levels with LJ Graph
Aspiration Volume 200 – 1500 µl
Air Aspiration Volume Variable (To reduce Carry over & Cross contamination)
Cross Contamination <1%
Temperature Control 25°C, 30°C, 37 °C Accuracy ±0.1°C, Peltier control
Operating Voltage 230 V, 50 Hz, 45 Watt max
Storage Temperature -10 to 40 °C
Operating Temperature 10 to 35 °C
Humidity ≤80% RH
Dimensions 245 (W) mm x 273 (D) mm x 299 (H) mm
Weight ~ 10 kgs
Language Supported English
Filter Check Manual
AVAILABILITY: In stock
AVAILABILITY: In stock
AVAILABILITY: In stock
AVAILABILITY: In stock