Product name
TERUFUSION Syringe Pump Type SS
model
TE-SS700/TE-SS800
Syringe size
5mL, 10mL, 20mL, 30mL, 50/60mL
Syringe brand
TERUMO or other speci ed brands
Dose mode (*: tE-SS800 only)
• mL/h mode • mg/kg/h mode (*)
• μg/kg/min mode (*) • Library mode (*)
Drug Library (tE-SS800 only)
3,000 Drugs 30 Pro les
flow rate setting range
• Setting range
0.01 to 150.00 mL/h
Note that the upper limit of the ow rate can be changed in the following ranges: 0.01 to 150.00 mL/h (when using syringe of 5 mL)
0.01 to 300.00 mL/h (when using syringe of 10, 20, 30 mL)
0.01 to 1200.00 mL/h (when using syringe of 50/60 mL)
• Step
0.01 mL/h step ( 0.01 to 10.00 mL/h)*
0.10 mL/h step ( 10.00 to 100.00 mL/h)*
1.00 mL/h step ( 100.00 to 1200.00 mL/h)*
*: Step can be used when ow rate is set by the Dial. (It will be 0.00 mL/h when the power is turned on.)
machine accuracy
Within ±1% ( ow rate ≥ 1.00 mL/h)
flow rate accuracy
accuracy including syringe
Within ±3%
(The hourly precision after one hour has passed since the start of infusion at a constant ow rate of 1.00 mL/h or more according to IEC 60601-2-24 standard.)
occlusion detection pressure
10 to 120kPa (set value)
The occlusion detection pressure can be set in 10 levels.
Purge ow rate
• Approx. 150 mL/h (when using syringe of 5mL) • Approx. 500 mL/h (when using syringe of 30mL)
• Approx. 300 mL/h (when using syringe of 10mL) • Approx. 1200 mL/h (when using syringe of 50/60mL)
• Approx. 400 mL/h (when using syringe of 20mL)
alarms
Occlusion alarm, Pressure alarm*1, Nearly Empty alarm, Clutch Displacement alarm, Syringe Barrel Detection alarm, Syringe Displacement alarm, Plunger Displacement alarm, Battery alarm, Re-alarm, Start Reminder, No Flow Rate alarm, No VTBI alarm*2, Flow Rate/VTBI Volume Judgment alarm*2, Completion alarm*2, Link Interruption alarm*1
*1: TE-SS800 only
*2: Only if the VTBI setting function is enabled (Default: disabled)
Safety functions
Remaining volume detection position function, Occlusion detection pressure select function, Bolus reduction function, Flow rate range setting function A (Soft limits), Flow rate range setting function B (Hard limits), Key lock function
use conditions
Ambient temperature: 5 to 40°C
Relative humidity: 20 to 90%RH (non-condensing)
Storage conditions
Ambient temperature: -20 to 45°C
Relative humidity: 10 to 95%RH (non-condensing)
Power supply
AC100 to 240V, 50 to 60Hz
Internal battery (lithium ion battery)
• Continuous use period: Approx. 12 hours (applies when solution is delivered continuously at 5 mL/h in ambient temperature of
25°C with new fully charged battery)
• Charging time: ≥8 hours (when charged with AC power supply with the power turned off)
Power consumption
24VA
classi cation
Class I equipment and internally powered equipment, type CF applied part, Continuous Operation, IP24
Wireless LaN (tE-SS800 only)
Hereby, TERUMO CORPORATION declares that this TERUFUSION Syringe Pump Type SS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
• Transmit frequency or frequency band: 2412 – 2472 MHz
• Type of modulation and frequency characteristics:
• Differential Binary Phase Shift Keying: DBPSK
• Differential Quadrature Phase Shift Keying: DQPSK • Effective radiated power: 10.7 dBm
• Direct Sequence Spread Spectrum: DSSS • Complementary code keying: CCK
Dimensions
Without external communication (RS-232C):
381 mm (W)*3 x 120 mm (H)*3 x 112 mm (D)*4
With external communication (RS-232C):
381 mm (W)*3 x 120 mm (H)*3 x 131 mm (D)*4
*3: Excluding protrusions, *4: Excluding protrusions, pole clamp and moving range
TERUMO SYRINGE PUMP SS700
Product name
TERUFUSION Syringe Pump Type SS
model
TE-SS700/TE-SS800
Syringe size
5mL, 10mL, 20mL, 30mL, 50/60mL
Syringe brand
TERUMO or other speci ed brands
Dose mode (*: tE-SS800 only)
• mL/h mode • mg/kg/h mode (*)
• μg/kg/min mode (*) • Library mode (*)
Drug Library (tE-SS800 only)
3,000 Drugs 30 Pro les
flow rate setting range
• Setting range
0.01 to 150.00 mL/h
Note that the upper limit of the ow rate can be changed in the following ranges: 0.01 to 150.00 mL/h (when using syringe of 5 mL)
0.01 to 300.00 mL/h (when using syringe of 10, 20, 30 mL)
0.01 to 1200.00 mL/h (when using syringe of 50/60 mL)
• Step
0.01 mL/h step ( 0.01 to 10.00 mL/h)*
0.10 mL/h step ( 10.00 to 100.00 mL/h)*
1.00 mL/h step ( 100.00 to 1200.00 mL/h)*
*: Step can be used when ow rate is set by the Dial. (It will be 0.00 mL/h when the power is turned on.)
machine accuracy
Within ±1% ( ow rate ≥ 1.00 mL/h)
flow rate accuracy
accuracy including syringe
Within ±3%
(The hourly precision after one hour has passed since the start of infusion at a constant ow rate of 1.00 mL/h or more according to IEC 60601-2-24 standard.)
occlusion detection pressure
10 to 120kPa (set value)
The occlusion detection pressure can be set in 10 levels.
Purge ow rate
• Approx. 150 mL/h (when using syringe of 5mL) • Approx. 500 mL/h (when using syringe of 30mL)
• Approx. 300 mL/h (when using syringe of 10mL) • Approx. 1200 mL/h (when using syringe of 50/60mL)
• Approx. 400 mL/h (when using syringe of 20mL)
alarms
Occlusion alarm, Pressure alarm*1, Nearly Empty alarm, Clutch Displacement alarm, Syringe Barrel Detection alarm, Syringe Displacement alarm, Plunger Displacement alarm, Battery alarm, Re-alarm, Start Reminder, No Flow Rate alarm, No VTBI alarm*2, Flow Rate/VTBI Volume Judgment alarm*2, Completion alarm*2, Link Interruption alarm*1
*1: TE-SS800 only
*2: Only if the VTBI setting function is enabled (Default: disabled)
Safety functions
Remaining volume detection position function, Occlusion detection pressure select function, Bolus reduction function, Flow rate range setting function A (Soft limits), Flow rate range setting function B (Hard limits), Key lock function
use conditions
Ambient temperature: 5 to 40°C
Relative humidity: 20 to 90%RH (non-condensing)
Storage conditions
Ambient temperature: -20 to 45°C
Relative humidity: 10 to 95%RH (non-condensing)
Power supply
AC100 to 240V, 50 to 60Hz
Internal battery (lithium ion battery)
• Continuous use period: Approx. 12 hours (applies when solution is delivered continuously at 5 mL/h in ambient temperature of
25°C with new fully charged battery)
• Charging time: ≥8 hours (when charged with AC power supply with the power turned off)
Power consumption
24VA
classi cation
Class I equipment and internally powered equipment, type CF applied part, Continuous Operation, IP24
Wireless LaN (tE-SS800 only)
Hereby, TERUMO CORPORATION declares that this TERUFUSION Syringe Pump Type SS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
• Transmit frequency or frequency band: 2412 – 2472 MHz
• Type of modulation and frequency characteristics:
• Differential Binary Phase Shift Keying: DBPSK
• Differential Quadrature Phase Shift Keying: DQPSK • Effective radiated power: 10.7 dBm
• Direct Sequence Spread Spectrum: DSSS • Complementary code keying: CCK
Dimensions
Without external communication (RS-232C):
381 mm (W)*3 x 120 mm (H)*3 x 112 mm (D)*4
With external communication (RS-232C):
381 mm (W)*3 x 120 mm (H)*3 x 131 mm (D)*4
*3: Excluding protrusions, *4: Excluding protrusions, pole clamp and moving range
-
Description
- |
-
Reviews (0)
- |
-
Add Tags
- |
Tail sed sausage magna quis commodo snasae. Aliquip strip steak esse ex in ham hock fugiat in. Labore velit pork belly eiusmod ut shank doner capicola consectetur landjaeger fugiat excepteur short loin. Pork belly laboris mollit in leberkas qui. Pariatur snasae aliqua pork chop venison veniam. Venison sed cow short loin bresaola shoulder cupidatat capicola drumstick dolore magna shankle.
AVAILABILITY: In stock
The original Defibtech AED includes all mission critical features necessary to provide the most advanced treatment for Sudden Cardiac Arrest. It is so simple and unintimidating to use that even non-medical personnel can effectively save lives.
Simple to Use
Simple, clear and straightforward: there are only two-buttons on the unit, a green button to turn the unit on and a red one to shock the patient, if needed.
Clear Voice Prompts
Saving lives, while rewarding, can be stressful. A calm voice leads the user through the rescue, clearly and concisely stating each instruction, one step at a time. Brightly lit progress lights provide clear visual text guidance to reinforce voice instructions.
AVAILABILITY: In stock
Uni-pro incubator is designed to meet the safest and most stable environment. This Incubator offers the Advanced Technology and Innovative design to meet the most demanding Neonatal Clinical care need in the NICU. Microprocessor based Temperature controller system provided to control the Air/Skin temperature and it has all Fault Indications with visual alarms.
AVAILABILITY: In stock
E- Flo Anaesthesia Workstations
BPL’s E-Flo series offer compact and reliable critical care solutions. Designed by keeping robustness and reliability in mind, these workstations come integrated with features that support all-round efficiency.
AVAILABILITY: In stock
Value without Compromise
Digital PID Pressure controlled function
Three channel Autocpap algorithm (Apnea – Snoring –Upper Respiratory Tract Resistance)
Medicraft Autocpap function method
Sensitive Snore detection thanks to digital filter that is applied with high speed sampling
Maximum, minimum and start up pressur setting
4-20 mbar pressure range
Multilanguage menu
Smart 4 button system
Wide graphic LCD screen
Automatic accessory detection system
Data connection port
Ramp function
Mask test
Clinic menu lock
Automatic start – stop
Optional Accessories
Humidifier (5 Stagr heater)
Li-lon battery (8 saat)
Cigarette Lighter Adapter
AVAILABILITY: In stock
SURTRON® HP can be used to simultaneously perform monopolar and bipolar surgery in application fields which require high precision and reliability.
Double Activity ‘Operating
Two output channels for monopolar cutting
Two independent setting and output channels for monopolar coagulation more frequently
Controlled Cutting Procedures
Cutting currents intensified for eschar free incision
Cutting current with selectable coagulating property for bleeding controlled dissection
Low capacitive coupling by current endoscopic procedures Slow BLEND
Double Procedures Coagulation Subsidiaries
SPEEDY * Coagulation and Coagulation DEEP ** available to two operators
Spray coagulation obtained with handpiece or
Bipolar cutting current with selectable bleeding control
Cutting current Slow BLEND
Start and Stop automatic coagulation activated separately
Acceptability of the impedance between the patient’s body contact and neutral plate constantly checked electronically dalcontrollo Skin Plate Electronic Control (SPEC)
Continuous radio frequency leakage current monitoring
Change in automatically compensated mains voltage before start of the radio frequency power delivery
Independent choice of coagulation currents and power levels of each of the two operators
Ten configurable personal procedures and immediately recallable
outputs for connections driven argon plasma units and smoke aspirator
Automatic diagnostic control of the actual complete electronic drive functionality and accessories connected and coded report of found failures
* Coagulation SPEEDY is also called Fulgurate or Forced
coagulation ** DEEP is also called Pin Point, or Dessicate Soft
AVAILABILITY: In stock
Silicone Gel Sheet for Scar Management.
Available in 5 x 5 cm, 10x10cm, 20x20cm and 40x40cm
Also available in customised sizes.
Lysil Silicone Gel Sheet For Scar Treatment
AVAILABILITY: In stock
RESCUE Life
General Specifications
Capacity 100 shocks at 230J with battery fully charged
Software Voice and texts multilanguage
Memory Internal flash 2 Gb up to 300 hrs of ECG data, events and usage review
AC 100-240 VAC, 50/60 Hz
Defibrillation
Waveform Bipashic Truncated Exponential (BTE)
HiCAP technology (Large storage capacitor)
Manual mode
ECG Monitoring
Display high contrast TFT color LCD 5.7″ (320 x 240 pixels)
Operational information, ECG traces, Spo2 value,
parameters, Heart Rate indicator, filters, alarms and battery status
Printer
Type Integrated thermal printer for ECG traces and events
documentation hardcopy including HR/SpO2 values
Options (not included)
– External pacemaker
– SPO2
– AED mode
Standards & Safety
Standard IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2, Class II, type BF
CE Mark EEC 93/42 Medical device, class IIb
AVAILABILITY: In stock
On the whole, we are indulged in industry for manufacturing and supplying Steam Autoclaves. Fundamentally, the autoclaves are used for carrying out different kinds of industrial processes, which required elevated temperature and pressure that is unlike from ambient air pressure. Our proposed range is widely used in medical industry, laboratories and other sectors for sterilization purposes. Moreover, the autoclaves are required for sterilizing the rubber products, medical product, microbial culture and different dentistry products. Steam Autoclaves work on the principal of different level of pressure.
AVAILABILITY: In stock
Uni-pro Baby Incubator is designed to meet the safest and most stable environment. This Incubator offers the Advanced Technology and Innovative design to meet the most demanding Neonatal Clinical care need in the NICU. Microprocessor based Temperature controller system provided to control the Air/Skin temperature and it has all Fault Indications with visual alarms.
AVAILABILITY: In stock
Super ability in against electrosurgical interference. Neither in cutting nor in burning, ECG waveform and HR can be influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room.
AVAILABILITY: In stock
Our Laboratory Autoclaves are demanded in different sectors for removing humidity and perform good sterilization. Autoclaves are basically suited to the laboratories applications as these are pressure chamber work on elevated temperature and pressure. Different kinds of glassware, rubber products, surgical instruments and medical devices are treated inside it to remove any kind of moisture and micro organisms. This offered range is suitable for all kinds of liquid, glass and biohazard. Laboratory Autoclaves are available to our clients at cost effective rates.
AVAILABILITY: In stock
Value without Compromise
Digital PID pressure controlled function
Function in four different modes: CPAP,AUTOCPAP and BiLEVELS which is special to medicraft BiLEVEL device
4 Stage trigger sensibility
Tidal volume display
40 bpm triggering
Graphical monitoring of respiratory curve on display
IPAP – EPAP setting
Inspiration and expiration slope adjustment
4-25 mbar pressure range
Multilanguage menu
Smart 4 button system
Wide graphic LCD Screen
Automatic accessory detection system
Data connection port
Ramp function
Mask test
Clinic menu lock
Automatic start stop
Optional Accessories
Humidifier ( 5 Stagr heater)
Li – lon battery (8 saat)
Cigarette Lighter Adapter
Reviews
There are no reviews yet.