TERUMO SYRINGE PUMP SS700


Product name
TERUFUSION Syringe Pump Type SS
model
TE-SS700/TE-SS800
Syringe size
5mL, 10mL, 20mL, 30mL, 50/60mL
Syringe brand
TERUMO or other speci ed brands
Dose mode (*: tE-SS800 only)
• mL/h mode • mg/kg/h mode (*)
• μg/kg/min mode (*) • Library mode (*)
Drug Library (tE-SS800 only)
3,000 Drugs 30 Pro les
flow rate setting range
• Setting range
0.01 to 150.00 mL/h
Note that the upper limit of the ow rate can be changed in the following ranges: 0.01 to 150.00 mL/h (when using syringe of 5 mL)
0.01 to 300.00 mL/h (when using syringe of 10, 20, 30 mL)
0.01 to 1200.00 mL/h (when using syringe of 50/60 mL)
• Step
0.01 mL/h step ( 0.01 to 10.00 mL/h)*
0.10 mL/h step ( 10.00 to 100.00 mL/h)*
1.00 mL/h step ( 100.00 to 1200.00 mL/h)*
*: Step can be used when ow rate is set by the Dial. (It will be 0.00 mL/h when the power is turned on.)
machine accuracy
Within ±1% ( ow rate ≥ 1.00 mL/h)
flow rate accuracy
accuracy including syringe
Within ±3%
(The hourly precision after one hour has passed since the start of infusion at a constant ow rate of 1.00 mL/h or more according to IEC 60601-2-24 standard.)
occlusion detection pressure
10 to 120kPa (set value)
The occlusion detection pressure can be set in 10 levels.
Purge ow rate
• Approx. 150 mL/h (when using syringe of 5mL) • Approx. 500 mL/h (when using syringe of 30mL)
• Approx. 300 mL/h (when using syringe of 10mL) • Approx. 1200 mL/h (when using syringe of 50/60mL)
• Approx. 400 mL/h (when using syringe of 20mL)
alarms
Occlusion alarm, Pressure alarm*1, Nearly Empty alarm, Clutch Displacement alarm, Syringe Barrel Detection alarm, Syringe Displacement alarm, Plunger Displacement alarm, Battery alarm, Re-alarm, Start Reminder, No Flow Rate alarm, No VTBI alarm*2, Flow Rate/VTBI Volume Judgment alarm*2, Completion alarm*2, Link Interruption alarm*1
*1: TE-SS800 only
*2: Only if the VTBI setting function is enabled (Default: disabled)
Safety functions
Remaining volume detection position function, Occlusion detection pressure select function, Bolus reduction function, Flow rate range setting function A (Soft limits), Flow rate range setting function B (Hard limits), Key lock function
use conditions
Ambient temperature: 5 to 40°C
Relative humidity: 20 to 90%RH (non-condensing)
Storage conditions
Ambient temperature: -20 to 45°C
Relative humidity: 10 to 95%RH (non-condensing)
Power supply
AC100 to 240V, 50 to 60Hz
Internal battery (lithium ion battery)
• Continuous use period: Approx. 12 hours (applies when solution is delivered continuously at 5 mL/h in ambient temperature of
25°C with new fully charged battery)
• Charging time: ≥8 hours (when charged with AC power supply with the power turned off)
Power consumption
24VA
classi cation
Class I equipment and internally powered equipment, type CF applied part, Continuous Operation, IP24
Wireless LaN (tE-SS800 only)
Hereby, TERUMO CORPORATION declares that this TERUFUSION Syringe Pump Type SS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
• Transmit frequency or frequency band: 2412 – 2472 MHz
• Type of modulation and frequency characteristics:
• Differential Binary Phase Shift Keying: DBPSK
• Differential Quadrature Phase Shift Keying: DQPSK • Effective radiated power: 10.7 dBm
• Direct Sequence Spread Spectrum: DSSS • Complementary code keying: CCK
Dimensions
Without external communication (RS-232C):
381 mm (W)*3 x 120 mm (H)*3 x 112 mm (D)*4
With external communication (RS-232C):
381 mm (W)*3 x 120 mm (H)*3 x 131 mm (D)*4
*3: Excluding protrusions, *4: Excluding protrusions, pole clamp and moving range


Share it:

Product name
TERUFUSION Syringe Pump Type SS
model
TE-SS700/TE-SS800
Syringe size
5mL, 10mL, 20mL, 30mL, 50/60mL
Syringe brand
TERUMO or other speci ed brands
Dose mode (*: tE-SS800 only)
• mL/h mode • mg/kg/h mode (*)
• μg/kg/min mode (*) • Library mode (*)
Drug Library (tE-SS800 only)
3,000 Drugs 30 Pro les
flow rate setting range
• Setting range
0.01 to 150.00 mL/h
Note that the upper limit of the ow rate can be changed in the following ranges: 0.01 to 150.00 mL/h (when using syringe of 5 mL)
0.01 to 300.00 mL/h (when using syringe of 10, 20, 30 mL)
0.01 to 1200.00 mL/h (when using syringe of 50/60 mL)
• Step
0.01 mL/h step ( 0.01 to 10.00 mL/h)*
0.10 mL/h step ( 10.00 to 100.00 mL/h)*
1.00 mL/h step ( 100.00 to 1200.00 mL/h)*
*: Step can be used when ow rate is set by the Dial. (It will be 0.00 mL/h when the power is turned on.)
machine accuracy
Within ±1% ( ow rate ≥ 1.00 mL/h)
flow rate accuracy
accuracy including syringe
Within ±3%
(The hourly precision after one hour has passed since the start of infusion at a constant ow rate of 1.00 mL/h or more according to IEC 60601-2-24 standard.)
occlusion detection pressure
10 to 120kPa (set value)
The occlusion detection pressure can be set in 10 levels.
Purge ow rate
• Approx. 150 mL/h (when using syringe of 5mL) • Approx. 500 mL/h (when using syringe of 30mL)
• Approx. 300 mL/h (when using syringe of 10mL) • Approx. 1200 mL/h (when using syringe of 50/60mL)
• Approx. 400 mL/h (when using syringe of 20mL)
alarms
Occlusion alarm, Pressure alarm*1, Nearly Empty alarm, Clutch Displacement alarm, Syringe Barrel Detection alarm, Syringe Displacement alarm, Plunger Displacement alarm, Battery alarm, Re-alarm, Start Reminder, No Flow Rate alarm, No VTBI alarm*2, Flow Rate/VTBI Volume Judgment alarm*2, Completion alarm*2, Link Interruption alarm*1
*1: TE-SS800 only
*2: Only if the VTBI setting function is enabled (Default: disabled)
Safety functions
Remaining volume detection position function, Occlusion detection pressure select function, Bolus reduction function, Flow rate range setting function A (Soft limits), Flow rate range setting function B (Hard limits), Key lock function
use conditions
Ambient temperature: 5 to 40°C
Relative humidity: 20 to 90%RH (non-condensing)
Storage conditions
Ambient temperature: -20 to 45°C
Relative humidity: 10 to 95%RH (non-condensing)
Power supply
AC100 to 240V, 50 to 60Hz
Internal battery (lithium ion battery)
• Continuous use period: Approx. 12 hours (applies when solution is delivered continuously at 5 mL/h in ambient temperature of
25°C with new fully charged battery)
• Charging time: ≥8 hours (when charged with AC power supply with the power turned off)
Power consumption
24VA
classi cation
Class I equipment and internally powered equipment, type CF applied part, Continuous Operation, IP24
Wireless LaN (tE-SS800 only)
Hereby, TERUMO CORPORATION declares that this TERUFUSION Syringe Pump Type SS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
• Transmit frequency or frequency band: 2412 – 2472 MHz
• Type of modulation and frequency characteristics:
• Differential Binary Phase Shift Keying: DBPSK
• Differential Quadrature Phase Shift Keying: DQPSK • Effective radiated power: 10.7 dBm
• Direct Sequence Spread Spectrum: DSSS • Complementary code keying: CCK
Dimensions
Without external communication (RS-232C):
381 mm (W)*3 x 120 mm (H)*3 x 112 mm (D)*4
With external communication (RS-232C):
381 mm (W)*3 x 120 mm (H)*3 x 131 mm (D)*4
*3: Excluding protrusions, *4: Excluding protrusions, pole clamp and moving range

Reviews

There are no reviews yet.

Be the first to review “TERUMO SYRINGE PUMP SS700”

Your email address will not be published. Required fields are marked *

Custom Tab Content here.
Tail sed sausage magna quis commodo snasae. Aliquip strip steak esse ex in ham hock fugiat in. Labore velit pork belly eiusmod ut shank doner capicola consectetur landjaeger fugiat excepteur short loin. Pork belly laboris mollit in leberkas qui. Pariatur snasae aliqua pork chop venison veniam. Venison sed cow short loin bresaola shoulder cupidatat capicola drumstick dolore magna shankle.